制服丝祙亚洲av,中文亚洲精品无码,水蜜桃成视频人在线播放,日本久久久久久久久精品,julia无码中文字幕在线,成人午夜sm精品久久久久久久,久久久精品成人免费看片

Silencer typePipeline silencer生產(chǎn)廠家型號(hào)規(guī)格
Your location : Home > Product > Silencer type
Pipeline silencer
Pipeline silencer
Pipeline silencer
Pipeline silencer

Pipeline silencer

Pipeline silencers are mainly used for silencing the steam emissions of thermal equipment such as boilers and steam turbines in the power generation department. The noise reduction capacity of the pipeline muffler can meet the requirements of the Industrial Enterprise Noise Hygiene Standard.
Online inquiry
上一產(chǎn)品 : Combination fan silencer
下一產(chǎn)品 : Axial flow fan silencer
  • Content details

Introduction to Pipeline Silencers:


Pipeline silencers (silencers) are mainly used for silencing the steam emissions of thermal equipment such as boilers and steam turbines in the power generation department.


Purpose of pipeline muffler:


The noise emitted by steam emissions from steam boilers and related thermal equipment can reach up to 130 decibels, far exceeding the values specified in the Industrial Enterprise Noise Hygiene Standard issued by us. (For example, superheated steam with a gauge pressure of 1kg/cm2 can reach a velocity of 570-600 meters/second when discharged into the atmosphere through a hole, while for saturated steam, its velocity can also reach 470-480 meters/second. When such high-speed steam is discharged into the atmosphere, it causes high noise due to exceeding the sound velocity of 340 meters/second.). Noise reduction - results in meeting the requirements of the Industrial Enterprise Noise Hygiene Standards.


Pipeline silencer -:


Pipeline silencers (silencers) are mainly used for silencing the steam emissions of thermal equipment such as boilers and steam turbines in the power generation department. At the same time, it is also used for boiler steam emissions and other gas silencing emissions in industries such as petroleum, chemical, metallurgical, and textile. A suppressor is a device that prevents sound transmission and allows airflow to pass through, which is an important measure to eliminate steam emission power noise. To measure the effectiveness of an exhaust suppressor, the following three aspects are mainly considered:


1. The noise reduction capacity of the pipeline muffler can meet the requirements of the Industrial Enterprise Noise Hygiene Standard.


2. Adaptability of pipeline silencers; (i.e. adapting to low spectrum broadband and high temperature and high pressure).


3. The structure of pipeline eliminators. (Reasonable size, low construction, long, etc.).


The boiler steam in the power generation department not only has high temperature and high pressure, but also a wide emission frequency bandwidth. Relying solely on small hole noise reduction is not enough. The auxiliary exhaust steam eliminator is developed based on the principle of composite noise reduction of resistance, spray, and resistance. It has a large noise reduction amount, a wide adaptability frequency band, and is designed specifically for various parameters such as low pressure, - pressure, sub high pressure, high pressure, subcritical, and - critical, The silencer is made of stainless steel (1Cr18Ni9Ti, 12Cr1MoV) and is easy to install.


Principle of pipeline muffler:


The boiler exhaust steam eliminator is manufactured based on the principle of micro perforated plate noise reduction. The steam discharge from power plant boilers generally has a high flow rate, which has a significant impact on the noise reduction of small holes. So we need to control the flow, and the steam that passes through flow control will enter the expansion chamber and then be further depressurized and silenced. After the steam is depressurized by a large volume, it forms low-pressure steam and sprays out. During this process, the airflow is ejected through a small aperture. After spraying, the sound power of each octave band has decreased, and the frequency of sound pressure has been raised to above 20000Hz, greatly weakening its noise. But some frequencies of secondary noise still need to be further silenced. We are installing sound-absorbing cotton knots outdoors for expansion, which are designed based on the spectrum of residual noise emitted by the pressure reducing body, to effectively absorb residual noise. After the user installs according to the requirements, the total noise reduction should reach 30-60 decibels to meet the requirements.


Ordering selection:


The muffler is designed according to the user's emission target and requirements. Therefore, only when the production meets the emission target and parameters can significant noise reduction be achieved.


Therefore, when ordering consumers, the following information must be provided:


(1) Steam emissions - low (T/h), as well as pressure and temperature.


(2) Object of use (such as for boiler steam displacement or safety valve discharge, etc.).


(3) Outer diameter and wall thickness of exhaust pipe.


產(chǎn)品動(dòng)態(tài)

Pipeline silencer生產(chǎn)廠家Copyright ? 2012-2023 Lianyungang Lingdong Electromechanical Equipment Co., Ltd all rights reserved

Tel

0518-85370171